Wood Equilibrium Moisture Calculations for Flooring

By: webadmin

Written by: Home & Building Editorial Team (Residential Systems & Maintenance Desk)
Reviewed by: Home Systems Review Desk (Building Code & Specification Review)
Editorial Standard: Residential Reference Guide | Primary Source Verified — Cross-referenced with published building guidelines, manufacturer manuals & energy standards
Editorial Verification Standard: Technical parameters, comparative benchmarks, and procedural steps are cross-checked against primary documentation and published standards.

Equilibrium moisture content (EMC) dictates dimensional stability in solid and engineered wood flooring. Wood reaches EMC when internal moisture vapor pressure equals ambient vapor pressure. Standard residential interior conditions—70°F (21.1°C) dry-bulb temperature, 30% to 50% relative humidity (RH), require wood moisture content between 6.0% and 9.2%. Installation before reaching baseline EMC causes structural failure: cupping, crowning, buckled fasteners, surface check lines.

Executive Summary & Direct BLUF Answer: Wood Equilibrium Moisture Calculations

Comparative specification matrix contrasting primary options for wood equilibrium moisture content chart.
Comparative breakdown and verified evaluation parameters for wood equilibrium moisture content chart.

Wood behaves as hygroscopic, porous biomaterial. Cellulose, hemicellulose, lignin contain free hydroxyl groups ($\text{OH}^-$). Hydroxyl groups attract airborne water molecules via hydrogen bonding. Bound water occupies cell walls. Free water occupies cell lumina. Below fiber saturation point (FSP, typically 28% to 30% moisture content), wood gains or loses water mass solely inside cell walls. This mass transfer produces proportional dimensional change.

Standard interior living spaces require continuous conditioning. HVAC mechanical systems must maintain target range:

  • Interior temperature range: 60°F to 80°F (15.5°C to 26.7°C)
  • Interior relative humidity: 30% to 50%
  • Resulting target wood EMC: 6.0% to 9.2%

Acclimation failure directly drives flooring service calls. Wood flooring planks installed at 12% moisture content inside 35% RH home dry out toward 7% EMC. Loss of 5% bound water triggers tangential shrinkage. Floor boards develop longitudinal gaps, sheared edge cleat nails, split tongue-and-groove joints. Conversely, dry wood installed at 6% EMC inside humid 75% RH basement sub-environment absorbs water toward 14.4% EMC. Transverse swelling forces floor planks upward. Result: permanent board edge deformation (cupping), subfloor fastener pullout, systemic floor failure.

Hailwood-Horrobin thermodynamic sorption model predicts wood moisture equilibrium. Model accounts for dry-wood polymer mass, hydrated wood water mass, dissolved water vapor solution in cell wall structure. Hydration parameters shift non-linearly when ambient temperature or water vapor pressure changes:

$$EMC = \frac{1800}{W} \left[ \frac{K \cdot h}{1 – K \cdot h} + \frac{K_1 \cdot K \cdot h + 2 \cdot K_1 \cdot K_2 \cdot K^2 \cdot h^2}{1 + K_1 \cdot K \cdot h + K_1 \cdot K_2 \cdot K^2 \cdot h^2} \right]$$

Variables defined:

  • $h$: Relative humidity expressed as decimal ($\text{RH}% / 100$)
  • $W$: Molecular weight of dry wood cell-wall polymer per active sorption site
  • $K$: Equilibrium constant of dissolved water vapor relative to liquid water
  • $K_1$: Equilibrium constant of primary hydrated water addition to sorption site
  • $K_2$: Equilibrium constant of secondary hydrated water formation

Coefficients vary with dry-bulb temperature ($T$ in degrees Celsius):

  • $W = 349 + 1.29 \cdot T + 0.0135 \cdot T^2$
  • $K = 0.805 + 0.000736 \cdot T – 0.00000273 \cdot T^2$
  • $K_1 = 6.27 – 0.00933 \cdot T – 0.000461 \cdot T^2$
  • $K_2 = 1.91 + 0.0407 \cdot T – 0.000521 \cdot T^2$

Reference values derived from USDA Forest Service wood equilibrium moisture content calculations:

  • At 70°F (21.1°C) and 30% RH: $EMC = 6.2%$
  • At 70°F (21.1°C) and 50% RH: $EMC = 9.2%$
  • At 70°F (21.1°C) and 80% RH: $EMC = 16.0%$

Calculations show non-linear jump. Increase of 20% RH between 30% and 50% RH raises EMC by 3.0 percentage points. Increase of 30% RH between 50% and 80% RH raises EMC by 6.8 percentage points. Residential contractors must maintain 6% to 9% EMC target threshold. Exceeding threshold breaks warranty coverage under national floor finishing guidelines.

Technical & Regulatory Framework: Thermodynamic Laws and Industry Standards

Wood moisture equilibration operates under thermodynamic laws: Gibbs free energy reduction, chemical potential stabilization, capillary condensation. Ambient air holds partial vapor pressure ($p$). Saturated air holds saturation vapor pressure ($p_0$). Ratio $p / p_0$ equals relative humidity. When chemical potential of water vapor inside wood cell walls equals chemical potential of water vapor in ambient air, mass transfer stops ($dG = 0$).

Thermodynamic sorption hysteresis breaks symmetry between drying and wetting phases. Desorption branch (wood releasing moisture) yields higher EMC than adsorption branch (bone-dry wood absorbing moisture) at identical ambient RH and temperature. Ratio of adsorption EMC to desorption EMC averages 0.80 to 0.90 across hardwood species:

  • Kiln-dried flooring re-adsorbing interior air moisture at 50% RH, 70°F reaches ~8.5% EMC.
  • Green lumber drying down inside identical 50% RH, 70°F conditions equilibrates near 9.7% EMC.

Regulatory testing requires primary reference methods to calibrate pin and dielectric field meters. ASTM D4442 direct moisture content standards govern laboratory oven-dry procedures (Method A):

  1. Weigh initial specimen immediately upon field excision using balance calibrated to 0.01 g precision. Record mass as $M_{\text{initial}}$.
  2. Place test specimen inside ventilated convection oven maintained at $103^\circ\text{C} \pm 2^\circ\text{C}$ ($217^\circ\text{F} \pm 4^\circ\text{F}$).
  3. Dry specimen until mass change remains below 0.2% over consecutive 2-hour measurement intervals.
  4. Cool specimen inside desiccator containing anhydrous calcium sulfate desiccant to prevent atmospheric moisture pickup.
  5. Record final stable weight as oven-dry mass ($M_{\text{dry}}$).
  6. Calculate gravimetric moisture content using official baseline formula:
    $$MC% = \left( \frac{M_{\text{initial}} – M_{\text{dry}}}{M_{\text{dry}}} \right) \times 100$$

ASTM D4933 regulates laboratory conditioning of wood to equilibrium states. Closed psychrometric environmental chambers use aqueous saturated salt solutions to control target RH without refrigeration compressors:

  • Lithium Chloride ($\text{LiCl}$): maintains 11.3% RH at 20°C
  • Potassium Carbonate ($\text{K}_2\text{CO}_3$): maintains 43.2% RH at 20°C
  • Sodium Chloride ($\text{NaCl}$): maintains 75.3% RH at 20°C
  • Potassium Chloride ($\text{KCl}$): maintains 85.1% RH at 20°C

National Wood Flooring Association (NWFA) installation guidelines enforce strict baseline criteria before mechanical fastening:

  • Jobsite climate control systems must operate minimum 5 consecutive days prior to moisture testing.
  • Subfloor moisture must match flooring batch tolerance. Solid strip planks (<3 inches width) require subfloor-to-flooring differential under 4.0% MC. Wide plank flooring ($\ge 3$ inches width) requires differential under 2.0% MC.
  • Concrete slab subfloors require pre-installation testing under ASTM standards. ASTM F2170 concrete relative humidity threshold specifies internal relative humidity must not exceed 75% to 80% using in situ probe sensors placed at 40% slab depth (for slabs drying from one side) or 20% slab depth (for slabs drying from two sides). Equilibration probes require minimum 24-hour sensor thermal dwell time before final recording.

Empirical Benchmarks & Quantitative Comparative Analysis: Wood Equilibrium Moisture Content Chart

Structured procedural workflow protocol and sequential implementation checklist for wood equilibrium moisture content chart.
Structured operational timeline and protocol checklist for wood equilibrium moisture content chart.

Wood dimensional variation follows orthotropic grain directions:

  • Longitudinal shrinkage (parallel to tree trunk stem axis): negligible (0.1% to 0.2% total dimensional movement between green and oven-dry state).
  • Radial shrinkage (perpendicular to growth rings, cross-cut from pith to bark): moderate dimensional movement.
  • Tangential shrinkage (tangent to annual growth rings, parallel to bark surface): maximum movement. Typically 1.5 to 2.2 times greater than radial movement.

Plainsawn (flat-sawn) boards experience tangential expansion across plank width. Quartersawn and riftsawn boards experience radial expansion across plank width. Radial stability makes quartersawn planks less vulnerable to surface gaps.

Calculate anticipated dimensional change using species-specific shrinkage coefficients:

$$\Delta W = W_{\text{initial}} \times C \times \left( EMC_{\text{final}} – EMC_{\text{initial}} \right)$$

Variables:

  • $\Delta W$: Total width change (inches)
  • $W_{\text{initial}}$: Starting plank width (inches)
  • $C$: Dimensional change coefficient ($C_T$ for plainsawn tangential; $C_R$ for quartersawn radial)
  • $EMC_{\text{final}} – EMC_{\text{initial}}$: Shift in wood equilibrium moisture content percentage points

Empirical data published in seasonal indoor wood equilibrium moisture values documents continental US indoor EMC swings from 4% in winter heating environments to 13% in unconditioned summer conditions.

Matrix below displays verified equilibrium values across operational dry-bulb temperatures and ambient relative humidity levels. Data incorporates Hailwood-Horrobin model calibrations. This reference forms core wood equilibrium moisture content chart for flooring inspections:

Temperature (°F) 20% RH 30% RH 40% RH 50% RH 60% RH 70% RH 80% RH 90% RH
50°F (10.0°C) 4.6% 6.3% 7.9% 9.5% 11.3% 13.5% 16.5% 21.0%
55°F (12.8°C) 4.6% 6.3% 7.9% 9.5% 11.3% 13.4% 16.4% 20.9%
60°F (15.6°C) 4.6% 6.2% 7.8% 9.4% 11.1% 13.3% 16.2% 20.7%
65°F (18.3°C) 4.5% 6.2% 7.7% 9.3% 11.0% 13.1% 16.1% 20.5%
70°F (21.1°C) 4.5% 6.2% 7.7% 9.2% 10.9% 13.0% 16.0% 20.4%
75°F (23.9°C) 4.4% 6.1% 7.5% 9.1% 10.7% 12.8% 15.8% 20.2%
80°F (26.7°C) 4.3% 6.0% 7.4% 8.9% 10.6% 12.6% 15.6% 20.0%
85°F (29.4°C) 4.2% 5.8% 7.3% 8.8% 10.4% 12.4% 15.4% 19.7%
90°F (32.2°C) 4.1% 5.7% 7.1% 8.6% 10.2% 12.2% 15.1% 19.4%

Species respond unevenly to identical moisture shifts. Cell wall thickness, lumen volume, extractives concentration alter dimensional change coefficients ($C$). Table below details mechanical shrinkage metrics, fiber saturation points, dimensional coefficients for common residential flooring species:

Common Species Name Botanical Taxon Total Radial Shrinkage (%) Total Tangential Shrinkage (%) Radial Coefficient ($C_R$) Tangential Coefficient ($C_T$) Fiber Saturation Point ($MC_{\text{fsp}}$)
Northern Red Oak Quercus rubra 4.0% 8.6% 0.00158 0.00369 30%
White Oak Quercus alba 5.6% 10.5% 0.00180 0.00365 30%
Sugar (Hard) Maple Acer saccharum 4.8% 9.9% 0.00165 0.00353 30%
Black Walnut Juglans nigra 5.5% 7.8% 0.00190 0.00274 28%
Hickory (Shagbark) Carya ovata 7.0% 10.5% 0.00259 0.00411 30%
Yellow Birch Betula alleghaniensis 7.3% 9.5% 0.00256 0.00338 30%
Douglas-fir (Coast) Pseudotsuga menziesii 4.8% 7.6% 0.00174 0.00297 28%
American Cherry Prunus serotina 3.7% 7.1% 0.00144 0.00248 26%
Teak Tectona grandis 2.5% 5.8% 0.00100 0.00186 24%

Data applications show dimensional divergence. Example: 5-inch wide plainsawn plank subjected to interior moisture jump from 6.2% EMC (70°F, 30% RH) to 13.0% EMC (70°F, 70% RH). Absolute shift: $\Delta EMC = 6.8%$.

  1. Hickory (Carya ovata) tangential calculation:
    $$\Delta W = 5.0 \times 0.00411 \times 6.8 = 0.1397 \text{ inches per board}$$
    Ten adjacent boards expand cumulatively:
    $$10 \times 0.1397 = 1.397 \text{ inches total transverse lateral push}$$

  2. American Cherry (Prunus serotina) tangential calculation:
    $$\Delta W = 5.0 \times 0.00248 \times 6.8 = 0.0843 \text{ inches per board}$$
    Ten adjacent boards expand cumulatively:
    $$10 \times 0.0843 = 0.843 \text{ inches total transverse lateral push}$$

Hickory generates 65.7% more lateral expansion strain than American Cherry over identical ambient psychrometric shift. Perimeter expansion gaps cut to industry-standard 0.5-inch clearance will bind completely under Hickory expansion. Planks then lift vertically from subfloor fasteners, buckle across center field, crush plank edges permanently. Technical verification of species coefficients against equilibrium charts forms indispensable step for residential framing, underlayment specification, jobsite acclimation monitoring.

Practical Step-by-Step Implementation Protocol: Calculation to Planking

WOOD EQUILIBRIUM MOISTURE CONTENT CHART REFERENCE SUMMARY Key Specifications & Reference Criteria ★ Dry Winter Heating (21C 5.4% Target EMC Plank gap risk high ★ Standard Indoor Baseline 9.2% Target EMC Factory equilibrium reference ★ Humid Summer Coastal 14.4% Target EMC Edge cupping and buckling risk

Field installation demands strict hygrometric assessment protocol. Never rely on calendar time for wood acclimation. Follow this five-step ordered engineering sequence:

  1. Establish Conditioned Baseline: Run permanent HVAC equipment minimum 5 days before delivery. Maintain operational temperature between 18°C and 24°C (65°F–75°F). Maintain relative humidity between 30% and 50%. Log ambient coordinates twice daily using digital hygrometer with accuracy tolerance of ±2% RH.
  2. Profile Subfloor Moisture: Map subfloor moisture before introducing finish materials. For wood subfloors (plywood, OSB), take minimum 20 pin-meter readings per 1,000 sq ft. For concrete slabs, follow ASTM F2170 concrete relative humidity threshold standards: insert in situ relative humidity probes into drilled sleeves at 40% slab depth for single-pour drying, or 20% depth for slabs drying from two sides. Allow probes 24 hours equilibration before recording values. Concrete relative humidity must measure below 75% for standard adhesive systems, or below 85% for enhanced polymer systems.
  3. Derive Target Equilibrium Moisture Content: Cross-reference stable ambient temperature and relative humidity values against USDA Forest Service wood equilibrium moisture content calculations. Standard target equals 7.7% EMC at 21.1°C (70°F) and 40% RH.
  4. Calibrate Meter via Temperature and Species Factor: Adjust pin-type electrical resistance meters for wood core temperature and species group. Calculate true moisture content using temperature correction:

$$MC_{\text{corrected}} = \frac{MC_{\text{read}} + 0.567 – 0.0260(T + 2.8)}{0.881(1.0056)^T} + S$$

Where $T$ represents board temperature in degrees Celsius, and $S$ represents species correction factor derived under ASTM D4442 direct moisture content standards. For dielectric (pinless) meters, set gauge to correct specific gravity matrix. Verify reading depth matches cross-laminated or solid plank core thickness.
5. Execute Acclimation Verification and Core Testing: Unbox flooring material. Cross-stack inventory using 19 mm (3/4-inch) stickers between layers. Distribute air movement across stacks using low-velocity mechanical fans. Measure insulated core moisture by driving insulated contact pins into center third of plank thickness. Log minimum 40 readings per 1,000 board feet. Release wood for mechanical fastening or adhesive application only when average core moisture matches calculated target EMC within ±1% across three consecutive days.

Protocol Phase Measurement Technology Target Coordinate Limit Failure Trigger Condition Corrective Action
Ambient HVAC Digital Capacitive Hygrometer 30% to 50% RH, 18°C–24°C Variance > 10% RH across 24h Lock building envelope; adjust mechanical dehumidification
Wood Subfloor Insulated Pin Resistance ≤ 12% absolute MC Differential > 4% vs strip flooring, > 2% vs plank Defer delivery; heat subfloor assembly
Concrete Subfloor In Situ RH Probe (ASTM F2170) ≤ 75% internal RH (untreated) RH > 80% at 40% depth Apply Class I topical epoxy vapor barrier (< 0.1 perm)
Hardwood Stock Insulated Core Pin / Dielectric Target EMC ± 1.0% Variance > 2.0% within bundle Restack on 19 mm stickers; verify air circulation

Diagnostic Considerations, Edge Cases & Failure Mitigation

VAPOR DRIVE DYNAMICS IN CONFINED ASSEMBLIES:

[High RH Unconditioned Crawlspace / Hydronic Slab]
                   |
     High Vapor Pressure (P_v1)
                   |
                   v
       [Subfloor / Bottom Face]  <-- High Expansion Strain
     =============================  (Cupping Mechanism)
       [Top Finish / Ambient Air] <-- Dry Air Evaporation
                   ^
     Low Vapor Pressure (P_v2)
                   |
[Conditioned Interior: 21°C, 35% RH]

Radiant underfloor heating creates acute hygrometric gradients. Operating hydronic or electric radiant elements increases lower board face temperature. Bottom surface dries or overheats depending on subfloor vapor transmission. When slab retains residual moisture, radiant heat accelerates vapor pressure toward conditioned interior. Vapor encounters underside of flooring boards. Moisture differential between bottom face and top surface triggers mechanical distortion. Limit hydronic fluid temperatures to keep subfloor surface temperature below 29.4°C (85°F). Modulate surface temperature gradually: adjust settings maximum 1°C to 2°C (2°F–3°F) per 24-hour cycle during seasonal startup.

Crawlspace assemblies lacking Class I vapor retarders (permeance rating ≤ 0.05 perms) act as moisture reservoirs. Earth evaporation increases crawlspace relative humidity above 80%. Moisture migrates upward through subfloor structure toward low-pressure, air-conditioned living spaces above. Subfloor absorbs moisture. Bottom side of hardwood expands relative to top face, creating cupping. If topical sanding occurs while cupping persists, subsequent drying flattens bottom face, producing crowned floor profiles with permanent damage.

MECHANICAL DEFORMATION PATTERNS:

CUPPED PROFILE (Moisture High at Bottom, Low at Top):
  Top Face (Dry)       \________________/   (Shrinks/Hollow)
  Bottom Face (Wet)    /----------------\   (Swells/Expands)

CROWNED PROFILE (Post-Premature Sanding Result):
  Top Face (Sanded Flat While Cupped)  /----------------\  (Arched Center)
  Bottom Face (Dried Later)            \________________/  (Shrunk Flat)

Mitigate dimensional distortion by matching wood anatomical cut to site conditions. Quartersawn planks display lower dimensional change coefficients than plainsawn stock:

$$\Delta W = W_i \times C \times \Delta MC$$

Where $W_i$ represents initial plank width, $C$ represents dimensional change coefficient, and $\Delta MC$ represents moisture change below fiber saturation point (FSP).

Hardwood Species Anatomical Cut Tangential Coefficient ($C_T$) Radial Coefficient ($C_R$) Width Swell per 3% MC Delta (127 mm / 5-inch Plank) Critical Failure Limit
Northern Red Oak (Quercus rubra) Plainsawn 0.00369 — 1.41 mm (0.055 in) Compression set at > 1.8 mm swell
Northern Red Oak (Quercus rubra) Quartersawn — 0.00158 0.60 mm (0.024 in) Cleat pull-out at > 1.2 mm swell
Hard Maple (Acer saccharum) Plainsawn 0.00353 — 1.35 mm (0.053 in) Edge crush / splintering
Hard Maple (Acer saccharum) Quartersawn — 0.00165 0.63 mm (0.025 in) Shear failure at fasteners
Brazilian Cherry (Hymenaea courbaril) Plainsawn 0.00300 — 1.14 mm (0.045 in) Subfloor delamination
White Oak (Quercus alba) Plainsawn 0.00365 — 1.39 mm (0.055 in) Buckling / subfloor release

Wide plank flooring (face width ≥ 127 mm / 5 inches) amplifies absolute dimensional shift. Plainsawn Red Oak spanning 127 mm expands 1.41 mm under 3% moisture content shift. Across room width of 6 meters (47 boards), collective unrestrained expansion equals 66 mm. Install perimeter expansion gaps equal to total calculated expansion. For wide boards, apply elastomeric adhesive in conjunction with mechanical blind fasteners to distribute lateral shear strain evenly across subfloor assembly.


Frequently Asked Questions

How does field application of the Hailwood-Horrobin equation compare with reference data tables?
Field calculations require precise determination of wood equilibrium moisture content under varying conditions. The empirical Hailwood-Horrobin model uses temperature ($T$) and relative humidity ($H$) inputs:

$$EMC = \frac{1800}{W} \left[ \frac{K H}{1 – K H} + \frac{K_1 K H + 2 K_1 K_2 K^2 H^2}{1 + K_1 K H + K_1 K_2 K^2 H^2} \right]$$

Where:
$$W = 330 + 0.452 T + 0.00415 T^2$$
$$K = 0.791 + 0.000463 T – 0.000000844 T^2$$
$$K_1 = 6.34 + 0.000775 T – 0.0000935 T^2$$
$$K_2 = 1.09 + 0.0138 T – 0.0000904 T^2$$

Calculations yield identical values to standard tables. For rapid verification during installation, consult standardized reference values from USDA Forest Service wood equilibrium moisture content calculations. Cross-referencing field psychrometric conditions against calibrated tables eliminates calculation errors on site.

What are the exact subfloor-to-hardwood moisture differential limits?
Fastening wood flooring to plywood or OSB requires strict differential thresholds based on board width:

  • For strip flooring under 76 mm (3 inches) wide, moisture content differential between subfloor and planks must remain within 4% absolute MC.
  • For wide-plank flooring 76 mm (3 inches) or wider, differential must remain within 2% absolute MC.

Exceeding 2% differential on wide planks causes cupping, joint separation, and cleat tear-out as subfloor and surface layers equalize toward equilibrium.

How do geographic location and seasonal indoor shifts impact equilibrium baselines?
Regional atmospheric conditions dictate indoor design parameters. According to documented seasonal indoor wood equilibrium moisture values, winter space heating in interior continental zones drops indoor EMC down to 4% (21.1°C / 70°F at 20% RH). Humid coastal summer zones elevate unconditioned indoor EMC up to 13% (26.7°C / 80°F at 75% RH). Flooring acclimated to 10% MC will shrink severely in northern winter heating cycles, opening gaps. Acclimate hardwood to intermediate equilibrium baseline (6% to 9% MC) representing annual median psychrometric conditions for specific geographic zip code.

REGIONAL INTERIOR EMC RANGES (CONTINENTAL US):

Region                     Winter Indoor EMC    Summer Indoor EMC    Baseline Target
-------------------------------------------------------------------------------------
Northern Cold / Dry        4.0% - 5.5%          9.0% - 10.5%         7.0% - 8.0%
Humid Coastal / Southeast  8.0% - 9.5%          12.0% - 13.5%        10.0% - 11.0%
Desert Southwest           3.5% - 4.5%          6.0% - 7.5%          5.5% - 6.5%
Pacific Northwest          7.0% - 8.0%          10.5% - 11.5%        9.0% - 9.5%

How should contractors remediate flooring installed inside unconditioned spaces?
Do not sand distorted or buckled boards immediately. Follow structural recovery steps:

  1. Commission mechanical HVAC equipment to run continuously.
  2. Introduce low-grain industrial dehumidifiers to extract atmospheric vapor slowly. Drop relative humidity maximum 5% per 7-day period. Rapid drying induces surface checking, honeycombing, and end-splitting.
  3. Track plank core moisture levels weekly using calibrated insulated-pin meters.
  4. Allow 60 to 90 days for cross-sectional moisture gradients to normalize across entire board thickness.
  5. Once core readings stabilize within calculated target tolerance, evaluate residual deformation. Perform final fine sanding and refinishing only after transverse cupping flattens completely through hygrometric normalization.

References

  • Glass, S. V., & Zelinka, S. L. (2021). Moisture Relations and Physical Properties of Wood (Chapter 4, General Technical Report FPL-GTR-282). U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. https://www.fs.usda.gov/research/treesearch/62200
  • Simpson, W. T. (1998). Equilibrium Moisture Content of Wood in Outdoor Locations in the United States and Worldwide (Research Note FPL-RN-0268). U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. https://www.fs.usda.gov/research/treesearch/7279
  • ASTM International. (2020). Standard Test Methods for Direct Moisture Content Measurement of Wood and Wood-Based Materials (ASTM D4442-20). ASTM International. https://www.astm.org/d4442-20.html
  • ASTM International. (2019). Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes (ASTM F2170-19a). ASTM International. https://www.astm.org/f2170-19a.html

Leave a Comment